Mitsubishi Electric 800 Series Instruction Manual page 566

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Read/
Item
Write
Inverter reset
Write
Fault history clear
Write
Parameter clear
Write
All clear
Read
Parameter
Write
Read
Link parameter
Extended setting
Write
Read
Second parameter
changing
(instruction code
HFF = 1, 9)
Write
Write/
Multi command
Read
Inverter
Read
model
Capacity
Read

Refer to
page 556
for data formats (A, A1, A2, B, C, C1, D, E, E1, E2, E3, F)

Turning OFF the power supply while clearing parameters with H5A5A or H55AA returns the communication parameter settings to the initial
settings.

Refer to the calibration parameter list below for details on calibration parameters.

The gain frequency can be also written using Pr.125 (instruction code: H99) or Pr.126 (instruction code: H9A).
Instruction
code
H9696: Inverter reset
• As the inverter is reset at the start of communication by the computer, the
inverter cannot send reply data back to the computer.
HFD
H9966: Inverter reset
• After the computer correctly starts communication and send data to the
inverter, the inverter returns the ACK signal to the computer before being
reset.
HF4
H9696: Fault history is cleared.
All parameters return to initial values.
Whether to clear communication parameters or not can be selected
according to the data.
• Parameter clear
H9696: Parameters including communication parameters are cleared.
H5A5A: Parameters other than communication parameters are cleared.
• All parameter clear
H9966: Parameters including communication parameters are cleared.
HFC
H55AA: Parameters other than communication parameters are cleared.
For the details of whether or not to clear parameters, refer to
When a clear is performed with H9696 or H9966, communication related
parameter settings also return to the initial values. When resuming the
operation, set the parameters again.
Performing a clear will clear the instruction code HEC, HF3, and HFF
settings.
Only H9966 and H55AA (all parameter clear) are valid during the password
lock (refer to
page
Refer to the instruction code
H00 to H63
values as required.
When setting Pr.100 and later, the link parameter extended setting must be
H80 to HE3
set.
H7F
Parameter settings are changed (extended) according to the settings.
For details of the settings, refer to the instruction code
HFF
H6C
When setting the calibration parameters
H00: Frequency

H01: Parameter-set analog value
H02: Analog value input from terminal
HEC
Available for writing 2 commands, and monitoring 2 items for reading data
HF0
(refer to
page 568
Reading inverter model in ASCII code.
"H20" (blank code) is set for blank area
H7C
Example of "FR-A860-1"
H46, H52, H2D, H41, H38, H36, H30, H2D, H31, H20, H20 ......... H20
The capacity in the inverter model can be read in ASCII code.
Data is read in increments of 0.1 kW, and rounds down to 0.01 kW
increments
H7D
"H20" (blank code) is set for blank area
Example
0.75K......... "7" (H20, H20, H20, H20, H20, H37)
(N) Operation via communication and its settings
Data description
253).
(page
685) and write and/or read parameter

for detail)
Number of
data digits
(Format)
4 digits
(A and C/D)
4 digits
(A and D)
4 digits
(A and C/D)

4 digits

(A and C/D)
page
685.
4 digits
(B and E/D)
4 digits
(A and C/D)
2 digits
(B and E1/D)
(page
685).
2 digits
(A1 and C/D)
2 digits
(B and E1/D)
2 digits
(A1 and C/D)
10 digits
(A2 and C1/
D)
20 digits
(B and E3/D)
6 digits
(B and E2/D)
PARAMETERS
