 Removal (FR-A860-02890 or higher)
1) Remove the fan cover fixing screws, and remove the fan cover.
2) Disconnect the fan connector and remove the fan block.
3) Remove the fan fixing screws, and remove the fan.

The number of cooling fans differs according to the inverter capacity.
 Reinstallation (FR-A860-02890 or higher)
1) After confirming the orientation of the fan, reinstall the fan so that the arrow on the left of "AIR FLOW" faces up.
2) Install fans referring to the above figure.
NOTE
• Installing the fan in the opposite air flow direction can cause the inverter life to be shorter.
• Prevent the cable from being caught when installing a fan.
• Switch the power OFF before replacing fans. Since the inverter circuits are charged with voltage even after power OFF,
replace fans only when the inverter cover is on the inverter to prevent an electric shock accident.
3)
Fan connection
connector
<Fan side face>
PRECAUTIONS FOR MAINTENANCE AND INSPECTION

Fan
Fan block
2)
AIR FLOW
Inspection item
Fan cover
1)
663