Technical Specifications - Siemens Sinamics S120 Manual

Liquid-cooled chassis power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Motor Modules

6.6 Technical specifications

6.6
Technical specifications
Table 6- 11
Technical data for Motor Modules, 510 ... 720 V DC (line voltage 380 ... 480 V3 AC), Part 1
Article number
Type rating
- Based on I
(50 Hz 400 V)
L
- Based on I
(50 Hz 400 V)
H
- Based on I
(60 Hz 460 V)
L
- Based on I
(60 Hz 460 V)
H
Output current
- Rated current I
N A
- Base load current I
L
- Base load current I
H
- Max. output current I
max A
DC link current
Rated current I
when fed via
N DC
- Basic Line Module
- Active Line Module
Base load current I
when fed via
L DC
- Basic Line Module
- Active Line Module
Base load current I
when fed via
H DC
- Basic Line Module
- Active Line Module
Supply voltages
- Electronics power supply
- DC link voltage
- Output voltage
DC link capacitance
Rated pulse frequency
- Max. pulse frequency without derating
- Max. pulse frequency with derating
Electronics current consumption (24 V DC)
Cooling method
Power loss, max.
3)
- At 50 Hz 400 V
- At 60 Hz 460 V
- Dissipated to the ambient air
Max. coolant temperature
- without derating
- with derating
Rated flow rate
Pressure drop, typical
at the rated flow rate
4)
Liquid volume of integrated heat exchanger
Sound pressure level
L
(1 m) at 50/60 Hz
pA
222
6SL3325–
kW
1)
kW
1)
HP
2)
HP
2)
A
A
A
A
A
A
A
A
A
A
V
DC
V
DC
V
ACrms
μF
kHz
kHz
kHz
A
kW
kW
kW
°C
°C
l/min
Pa
dm³
dB(A)
1TE32-1AA3
1TE32–6AA3
110
132
90
110
150
200
150
200
210
260
205
250
178
233
307
375
256
317
230
287
250
305
225
274
227
284
195
255
24 (20.4 ... 28.8)
0 to 0.72 x DC link voltage
4800
5800
2
2
2
2
8
8
1.4
1.4
Liquid cooling with integrated stainless steel heat exchanger
1.61
1.95
1.68
2.06
0.06
0.07
45
45
50
50
9
9
70000
70000
0.31
0.31
52
52
Manual, (GH7), 11/2016, 6SL3097-4AM00-0BP7
1TE33-1AA3
1TE35–0AA3
160
250
132
200
250
400
200
350
310
490
302
477
277
438
453
715
380
600
340
538
368
581
331
522
338
534
303
480
510 ... 720
8400
9600
2
2
2
2
8
8
1.5
1.5
2.29
3.56
2.38
3.74
0.09
0.14
45
45
50
50
12
12
70000
70000
0.91
0.91
52
52
Liquid-cooled chassis power units

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simanics s120

Table of Contents