Technical Data - Siemens Sinamics S120 Manual

Liquid-cooled chassis power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Motor-side power components
7.4 dv/dt filter compact plus Voltage Peak Limiter
7.4.6

Technical data

Table 7- 27
Technical data of the dv/dt filter compact plus voltage peak limiter, 380 V ... 480 V 3 AC, Part 1
Article number
Suitable for Power Module
(unit rating)
Suitable for Motor Module
(unit rating)
I
thmax
Degree of protection
Power loss
- At 50 Hz
- At 60 Hz
- At 150 Hz
Terminals
- 1U1/1V1/1W1
- DCPS/DCNS
- 1U2/1V2/1W2
- PE
Max. permissible cable
length between dv/dt filter
and motor
Dimensions
Width
Height
Depth
Weight, approx.
290
6SL3000-
2DE32-6EA0
6SL3315-
1TE32-1AAx (110 kW)
1TE32-6AAx (132 kW)
6SL3325-
1TE32-1AAx (110 kW)
1TE32-6AAx (132 kW)
A
260
IP00
kW
0.210
kW
0.215
kW
0.255
for M10 bolt
for M8 screw
for M10 bolt
M6 screw
m
mm
310
mm
283
mm
238
kg
41
2DE35-0EA0
1TE33-1AAx (160 kW)
1TE35-0AAx (250 kW)
1TE33-1AAx (160 kW)
1TE35-0AAx (250 kW)
490
IP00
0.290
0.296
0.344
for M10 bolt
for M8 screw
for M10 bolt
M6 screw
100 (shielded)
150 (unshielded)
350
317
260
61
Liquid-cooled chassis power units
Manual, (GH7), 11/2016, 6SL3097-4AM00-0BP7
2DE38-4EA0
1TE36-1AAx (315 kW)
1TE37-5AAx (400 kW)
1TE38-4AAx (450 kW)
840
IP00
0.518
0.529
0.609
for M12 bolt
for M8 bolt
for M12 bolt
M6 screw
440
369
311
103