Operation Procedure
5. Select an RS485 port by pressing
and then press
.
There are three RS485 ports: RS485-1,
RS485-2, and RS485-3. The corresponding
port for RS485-1 is COM1; RS485-2 is
COM2; RS485-3 is COM3.
6. Set Baud Rate, Start Address and End
Address, and press
The following baud rates are supported:
4800bps, 9600bps and 19200bps. 9600bps
is recommended.
1≤Start Address ≤ End Address ≤ 247.
The address segments for these three ports
can overlap.
Set the address scope properly. The
broader the scope is, the longer the time is
for searching the devices.
7. Press
, select Ethernet, and press
8. Set IP address, Subnet Mask, Gateway,
and DNS, and press
NOTICE
Take the following precautions for setting Ethernet
parameters when the SmartLogger connects to the
Internet through a router:
Set the gateway address to the IP address of the
router.
Ensure that the IP address of the SmartLogger is
in the same network segment as the gateway
address.
Set the domain name server (DNS) address to the
IP address of the router or obtain the DNS
address from the network provider.