Functions
<Timing chart (Error 2)>
Light received
Light received
state
Light blocked
Control output
(OSSD 1 / 2)
External device
monitor input
Notes: 1) The response time depends on the number of beam channels.
Number of units in
series connection
Number of units in
parallel connection
4 to 48
49 to 96
97 to 127
128 to 144
145 to 192
193 to 256
2) Using the communication module SF4D-TM1 (option), you can change the allowed response time with-
in the range 100 to 600ms.
106
50ms or less
ON
OFF
ON
OFF
Main sensor
1 unit 2 units 3 units 4 units 0 unit 0 unit 1 unit 1 unit 2 units 2 units 3 units
1 unit
0 unit 0 unit 0 unit 0 unit 1 unit 2 units 1 unit 2 units 1 unit 2 units 1 unit
6ms
10ms 10ms 12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
8ms
10ms 10ms 12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
10ms
12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
−
12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
−
14ms 14ms 16ms 16ms 14ms 14ms
−
16ms 16ms 18ms 18ms
300ms or less
(Note 2)
Response time (OFF response)
Sub sensor
−
−
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
Lockout state
−
−
−
−
−
−
−
−
−
−