Wiring
The auxiliary output is used to invalid the external device monitor function. The auxiliary output
should be set to "control output negative logic" (factory setting). External devices cannot be con-
nected to the auxiliary output.
● Using line synchronization setting and 8-core cable
<Using PNP output>
Gray cable
Gray cable
(with black line)
Interlock function
External device monitor function Invalid
Auxiliary output
*Symbols
K1, K2: Safety relay unit, etc.
58
(Pale purple) Interlock setting input
(Brown) +V
(Pink) Test / Reset input
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Red) Auxiliary output
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Pale purple) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
Invalid (auto reset)