<Reference>
The series connection cable is used in common for both the emitter and receiver.
The length of the series connection cable varies by model No.
If this device is to be installed in an L-shaped layout configuration, we recommend that an at least
0.1m long series connection cable be used.
Model No.
SFD-CSL005
SFD-CSL01
SFD-CSL05
<Connecting the series connection cable>
Step 1 Loosen the two M2.6 screws on the end cap of the main sensor (emitter / receiver con-
nected by synchronization wire), and remove the end cap.
Step 2 Insert the connector of the series connection cable (option) into the connector on the
device. When inserting the connector, fit the cable into the groove on the device.
Connector
(16-pin)
Connector
Groove
Step 3 Tighten the two M2.6 screws. Tighten to a torque of 0.3N·m or less.
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
Length
0.05m
0.1m
0.5m
End cap
Main sensor (Top)
Cable for series connection
SFD-CSL□ (Option)
Cable
Sub sensor
(Bottom)
M2.6 screw
(Included with cable for series
connection)
Sub sensor
(Bottom)
Model No.
SFD-CSL1
SFD-CSL5
SFD-CSL10
M2.6 screw
Cable
Groove
Connector
Main sensor
(Top)
Mounting
Length
1m
5m
10m
Cable for series connection
SFD-CSL□ (Option)
Connector
(8-pin)
Main sensor
(Top)
M2.6 screw
(Included with cable for
series connection)