Basic Wiring - Panasonic SF4D Series Instruction Manual

Safety light curtain type 4
Hide thumbs Also See for SF4D Series:
Table of Contents

Advertisement

2-5-4 Basic Wiring

This is a common connection method whereby one emitter and one receiver face each other.
The control output (OSSD 1 / 2) turns OFF when light is blocked, and automatically turns ON
when light is received.
The output setting of the device is set by the connection of the output polarity setting / lockout release
input wire (pale blue).
If the wiring is not correct, the lockout state will activate.
● Using optical synchronization setting and 5-core cable
<Using PNP output>
Gray cable
Gray cable
(with black line)
*Symbols
K1, K2: Safety relay unit, etc.
<Using NPN output>
Gray cable
Gray cable
(with black line)
*Symbols
K1, K2: Safety relay unit, etc.
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
(Pink) Test input
(Brown) +V
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Pink) Test input
(Brown) +V
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
Wiring
+
24V DC
+20
%
-30
K1
+
24V DC
K2
+20
%
-30
+
24V DC
+20
%
-30
K1
+
24V DC
K2
+20
%
-30
57

Advertisement

Table of Contents
loading

Table of Contents