Mounting

2-4-3 Adding and Removing Sensors (Series Connection)

This section explains how to create a series connection using options.
To create a series connection, the following tasks must be performed.
● Take care not to misplace any screws while you are working.
● Keep the removed end cap in a safe place.
● Do not mix emitters and receiver in the series connection.
● There is packing on the connector of the bottom cap cable. If the packing is not fitted on the
connector properly, fit as shown below before connecting to the device.
● The shape of the connector on the SFD-CSL□ series connection cable (option) is different from
the bottom connector and end cap connector. Take care not to mix up the cables when installing.
● The series connection cable cannot be extended.
● When inserting the series connection cable into the main sensor, pay attention to the following
points. Risk of bending of connector pins if inserted carelessly.
1. Do not run the cable before you have fastened the connector with the M2.6 screws.
2. Make sure the connector is completely inserted before fastening with the M2.6 screws.
40
CAUTION
Fastened with M2.6 screw
Without gap
Not fastened with M2.6 screw
With gap
© Panasonic Industrial Devices SUNX Co., Ltd. 2017