*S1
Switch S1
● Test / Reset input
Manual reset ...0 to 2.5V (source current 5mA or less): Emission halt, Open: Emission
Auto reset ...0 to 2.5V (source current 5mA or less): Emission, Open: Emission halt
● Interlock setting input, Override input, Muting input A / B, External device monitor input
0 to +2.5V (source current 5mA or less): Valid, Open: Invalid
<Reference>
● K1, K2: External device (forcible guide relay or magnetic conductor)
● For wiring, refer to 2-5-4 and following sections.
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
Wiring