Panasonic SF4D Series Instruction Manual page 16

Safety light curtain type 4
Hide thumbs Also See for SF4D Series:
Table of Contents

Advertisement

Part Description
● Emitter/receiver common
Name
Upper application indicator
(Blue / Red / Green / Orange)
(Note 1)
Lower application indicator
(Blue / Red / Green / Orange)
(Note 1)
Stable light reception indicator
(Green / Orange)
Received
light intensity
(Green)
Digital indicator
(Green / Yellow)
Error (Yellow) Normal operation: Turns OFF, Error: Yellow number blinks or lights " "
Polarity
(Yellow)
Frequency indicator (Orange)
● Emitter
Name
Light emission intensity control
indicator (Orange) [CTRL]
Test indicator (Orange) [TEST] During test: Lights orange "
Operation indicator
(Red / Green) [OP]
● Receiver
Name
Function setting indicator
(Orange) [FUNC]
Interlock indicator (Yellow)
[LOCK]
OSSD indicator (Red / Green)
[OSSD]
Notes: 1) In the case of optical synchronization, the upper application indicator and lower application indicator on
the emitter remain OFF.
2) For details on the blanking function and parallel connection, refer to "3-11 Functions That Can be Set
Using the Optional Communication Module SF4D-TM1".
3) Names in brackets [ ] are names that are indicated on the device.
16
Line synchronization
<When beam axis alignment mode is set>
Control output (OSSD 1 / 2) ON: Lights blue "
When top end beam channel receives light: Lights red "
When top end beam channel is blocked: Turns OFF
<When application mode is set>
When application indicator input 1 is ON: Lights green "
When application indicator input 2 is ON: Lights red "
When application indicator input 1 / 2 are ON: Lights orange "
When application indicator input 1 / 2 are OFF: Turns OFF
<When beam axis alignment mode is set>
Control output (OSSD 1 / 2) ON: Lights blue "
When bottom end beam channel receives light: Lights red "
When bottom end beam channel is blocked: Turns OFF
<When application mode is set>
When application indicator input 1 is ON: Lights green "
When application indicator input 2 is ON: Lights red "
When application indicator input 1 / 2 are ON: Lights orange "
When application indicator input 1 / 2 are OFF: Turns OFF
When light reception is stable: Lights green "
When light reception is unstable: Lights orange "
When light is blocked: Turns OFF
Light intensity / Level 3: Lights green " "
Light intensity / Level 2: Lights green " "
Light intensity / Level 1: Lights green " "
When light is blocked: Turns OFF
When PNP output is set: Lights yellow " " (only during startup)
When NPN output is set: Lights yellow " " (only during startup)
-
Line synchronization
Short mode: Turns OFF, Long mode: Lights orange "
Control output (OSSD 1 / 2) OFF:
Lights red "
Control output (OSSD 1 / 2) ON:
Lights green "
Line synchronization
Communication module connected: Blinks orange "
Blanking function or parallel connection used: Lights orange "
Interlock activated: Lights yellow "
Control output (OSSD 1 / 2) OFF: Lights red "
Control output (OSSD 1 / 2) ON: Lights green "
Function
When frequency 1 is set: Lights orange "
When frequency 2 is set: Lights orange "
Function
", Normal operation: Turns OFF
"
Normal operation: Lights green "
Error: Lights red "
"
Function
", All other times: Turns OFF
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
Optical synchronization
"
"
"
"
"
"
"
"
"
"
"
"
Optical synchronization
"
"
Optical synchronization
"
" (Note 2)
"
"
"
"
"