Test Pattern Tool - Sharp PN-L803C Service Manual

Touch display / touch pen
Hide thumbs Also See for PN-L803C:
Table of Contents

Advertisement

18. TEST PATTERN TOOL

This tool is used to display the test pattern to check that the parts and the LCD module are securely connected after replacement, removal
or disassembly of the I/F PWB, the C-PWB, the LVDS cable, and the LCD module.
18-1.
OPERATING
PATTERN TOOL
The operating conditions of the test pattern tool of the information
display are as follows.
- Windows 8/8.1
OS
- Windows Vista
(32bit/64bit)
- Windows 7
- RS-232C port which is recognized as COM
port (with communication speed: 9600,
Communication
19200, 38400bps)
port
- LAN(100 BASE-TX / 10BASE-TX)
When connected to the information display
with a LAN cable
Connect the monitor and the PC by the cross cable or the straight
cable through the hub. When the monitor and the PC is connected
directly by the cross cable, the settings for the monitor and the PC
needs to be done.
When the monitor is connected to the network, ask your system
administrator about how to set the PC for connecting the monitor.
(MEMO)
This tool cannot be operated correctly when the monitor is in the
power waiting state or the signal waiting state. In this case, send
the input signal to the monitor or set the power management to
OFF.
18-2. BOOTING PROCEDURES OF THE TEST
PATTERN TOOL
Press [Test Pattern] button of the service tool launcher, and the
following message is displayed.
For connection of the jig, refer to the following.
Refer to page 4 - 35 "18. FLICKER ADJUSTMENT TOOL".
18-3. TEST PATTERN METHOD
GUI OF THE TEST PATTERN TOOL
PN-L803C/80TC3 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 36
CONDITIONS
OF
TEST
The test procedures by use of the test pattern tool are as follows:
1 ) Press [Connection Setting] button and perform the
communication setting.
2 ) When [UP] or [DOWN] button is pressed, the pattern is
changed in the sequence shown below.
3 ) When [EXIT] button is pressed, the tool is terminated. To
cancel the display pattern, turn OFF the main power.
TEST PATTERN
TRANSITION WHEN
[UP] IS PRESSED
PATTERN
TRANSITION
(UP SEQUENCE)
Gradaton holixzmtal
Up white, Down black
Up black, Down white
50%Gray
100%Gray
Green
Blue
Red
All black
Gradation vertical
*1 With only the B model, the holding [POWER] button function is
effective.
TEST PATTERN
TRANSITION WHEN
[DOWN] IS PRESSED
PATTERN
TRANSITION
(DOWN SEQUENCE)
All black
Red
*1
Blue
*1
Green
100%Gray
50%Gray
Gradation horizontal
Gradation vertica
Up black, Down white
Up white, Down black
All black
*1
l
*1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pn-80tc3Pn-zl03

Table of Contents