5 – 3. METHOD3
Check with the "STATUS[XXXX]" number.
1) When an error occurs, four-digit figures are displayed after the
message of "STATUS" on the left lower section of the screen.
They are assigned as follows.
Bit
0
SYSTEM POWER1
1
SYSTEM POWER2
2
SYSTEM POWER3
3
SYSTEM POWER4
4
SYSTEM POWER5
5
BACKLIGHT
6
TOUCH PANEL
7 - 10
Reserved
11
Low voltage abnormality
12 - 13
Reserved
14
Temperature sensor abnormality
15
Temperature abnormality
5 – 4. METHOD4
Check with the item of "STATUS" on the "Product information
(INFORMATION)" screen.
When [DISPLAY] button is pressed, the "INFORMATION" screen
is displayed.
Check with the "STATUS" item on the screen.1) When an error
occurs, four-digit figures are displayed after the message of
"STATUS" on the left lower section of the screen. They are
assigned as follows.
INFORMATION1
INPUT MODE
SIZE
COLOR MODE
BRIGHT
VOLUME
ID No.
MODEL
S/N
STATUS
XXXX-XXXX-XXXX-XXXX
TOUCH PANEL
LAN
1920x1080 V:999Hz H:999.9kHz
PN-L803C/80TC3 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 6
PN-L703A
Hardware monitoring result
A
The number of controls of
the backlight when a
B
temperature abnormality
occurs
Accumulated control time of
the backlight when a
C
temperature abnormality
occurs
Number of shifts to the
power standby state when a
D
temperature abnormality
occurs
Reserved
E
(Not used for this time)
Reserved
F
(Not used for this time)
It takes some time necessary for judgment of a temperature
abnormality and a hardware abnormality as shown below:
- Temperature abnormality:
Min. 2 minutes (Exceeding the threshold value 3 times
continuously in the interval of 1 minute).
- Hardware abnormality:
Min. 18 seconds (Exceeding the threshold value 4 times
continuously in the interval of 6 seconds).
Though, therefore, the threshold value is exceeded on the
"HARDWARE CHECK" screen of SERVICE MANU 2 or in the
periodic send/ test mail, "OK" may be displayed.
In addition, when "NG" judgment is made once, "NG" state is
maintained until the power is turned OFF/ON. Even if, therefore,
the target value is reduced below the threshold value, the
judgment may be "NG" with a normal value.
The error detection position is
displayed with the same number
as the "METHOD 3".
Displayed in 2 digits.
For more than 99 times, "99" is
displayed.
Displayed in 2 digits.
For more than 99 hours, "99" is
displayed.
Displayed in 2 digits.
For more than 99 times, "99" is
displayed.