(MEMO)
- Up to 8 SCHEDULE items can be registered.
- Setting the SCHEDULE flashes the power LED alternately in red and orange in standby mode.
- A SCHEDULE that has a large number has precedence over that of a small number when schedules overlap.
- When START INPUT MODE is set to WHITEBOARD, the screen that appears when the power on schedule is executed is WHITEBOARD
regardless of the INPUT setting.
- When executing a power off schedule, if there is unsaved data on the WHITEBOARD, a data save message will appear about once a
minute starting about 5 minutes prior to power off. Save data you need. When the power turns off, the data will be lost.
3 - 2.INITIALIZATION (RESET)/FUNCTIONAL RESTRICTION SETTING (FUNCTION)
You can return the settings to their factory-preset values and restrict operations.
1. Hold
down until "F" appears in the upper left corner of the screen.
2. While "F" appears, press
3. Select and set the items.
ALL RESET
ADJUSTMENT
LOCK
ADJUSTMENT
LOCK TARGET
RS-232C/LAN
OSD DISPLAY
LED
TEMPERATURE
ALERT
STATUS ALERT
PN-L803C/80TC3 INSTALLATION, ADJUSTMENT, SETTING, OPERATION 2 - 32
Resets the settings to the factory default settings.
Press
, select the resetting method, and then press
After initialization, turn the main power switch off and then back on.
ALL RESET1.....Resets all the settings to the factory default settings.
ALL RESET2.....Returns all settings to the factory default settings except for the following items:
LAN SETUP, RS-232C/LAN SELECT, BAUD RATE, NETWORK, MAIL, SERVICE &
SUPPORT, and SNMP
You can disable operations on the monitor and the remote control unit that use buttons.
OFF....Enables operation.
ON 1...Disables all operations other than turning power on/off and FUNCTION.
ON 2...Only the FUNCTION operation is enabled.
Disables all operations other than FUNCTION (not even power on/off).
When STANDBY MODE is set to LOW POWER, ON 2 cannot be set.
Sets the target to prohibit operation of with ADJUSTMENT LOCK.
REMOTE CONTROL...... Prohibits remote control operation
MONITOR BUTTONS.... Prohibits monitor button operation
BOTH.............................. Prohibits remote control and monitor button operation
Specifies whether to allow control via RS-232C or LAN.
Shows/hides the menu, modes and messages.
The FUNCTION screen cannot be hidden.
ON 1............... Shows all menus, modes and messages.
ON 2............... Hides messages automatically displayed by the display. Shows messages during operation.
OFF................ Hides all menus, modes and messages.
Specifies whether to light the power LED.
Selects the notification method for an abnormal temperature.
OFF............... Do not notify about an abnormal temperature.
OSD & LED... When an abnormal temperature is detected, the power LED flashes in red and green
alternately and the screen displays a message: TEMPERATURE.
LED............... When an abnormal temperature is detected, the power LED flashes in redand green
alternately.
Selects the notification method for a hardware error.
in that order.
.