9. USAGE TIME SETTING PROCEDURE

9-1. OPERATING CONDITIONS OF THE USAGE
TIME SETTING TOOL
The operating conditions of the Gamma setting read tool of the
information display are as follows.
- Windows 8/8.1
OS
- Windows Vista
(32bit/64bit)
- Windows 7
- RS-232C port which is recognized as COM
port (with communication speed: 9600,
Communication
19200, 38400bps)
port
- LAN(100 BASE-TX / 10BASE-TX)
When connected to the information display
with a LAN cable
Connect the monitor and the PC by the cross cable or the straight
cable through the hub. When the monitor and the PC is connected
directly by the cross cable, the settings for the monitor and the PC
needs to be done.
When the monitor is connected to the network, ask your system
administrator about how to set the PC for connecting the monitor.
(MEMO)
This tool cannot be operated correctly when the monitor is in the
power waiting state or the signal waiting state. In this case, send
the input signal to the monitor or set the power management to
OFF.
9-2. START-UP OF THE USAGE TIME SETTING
TOOL
Press [Usage Time] button of the Service Tool Launcher.
PN-L803C/80TC3 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 16
9-3. USAGE TIME SETTING PROCEDURES
The procedures of setting usage time with use of the Usage Time
Setting Tool are as follows.
1) Press [Connection Setting...] button to configure the
communication settings.
2) Input the usage time you need to set in the field of Write Data.
It should be from "000000" to "200000." Make sure to input a
6-digit number.
3) Press [Write] button.
4) Press [Read] button, and confirm that the set usage time is
displayed in the Read Data field.
9-4. USAGE TIME CHECK PROCEDURE
With an image displayed on the display, use the accessory remote
controller to enter the SERVICE MENU 1, and check the USAGE
TIME on the column of USAGE TIME.
To enter the SERVICE MENU 1, press and hold [SIZE] button on
the remote controller for 5 sec, and press the buttons in the
sequence of [VOL + ()], [VOL - ()], [BRIGHT - ( )],[BRIGHT +
()].