10. MODEL NAME SETTING PROCEDURES

10-1. OPERATING CONDITIONS OF THE MODEL
NAME SETTING TOOL
The operating conditions of the Gamma setting read tool of the
information display are as follows.
- Windows 8/8.1
OS
- Windows Vista
(32bit/64bit)
- Windows 7
- RS-232C port which is recognized as COM
port (with communication speed: 9600,
Communication
19200, 38400bps)
port
- LAN(100 BASE-TX / 10BASE-TX)
When connected to the information display
with a LAN cable
Connect the monitor and the PC by the cross cable or the straight
cable through the hub. When the monitor and the PC is connected
directly by the cross cable, the settings for the monitor and the PC
needs to be done.
When the monitor is connected to the network, ask your system
administrator about how to set the PC for connecting the monitor.
(MEMO)
This tool cannot be operated correctly when the monitor is in the
power waiting state or the signal waiting state. In this case, send
the input signal to the monitor or set the power management to
OFF.
10-2. START-UP OF THE MODEL NAME SETTING
TOOL
Press [Model Name] button of the Service Tool Launcher.
PN-L803C/80TC3 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 17
10-3. MODEL NAME SETTING PROCEDURES
The procedures of setting model names with use of the Model
Name Setting Tool are as follows.
1) Input the model name in the field of Write Data.
Normally, the model name has been already input at the time of
start-up. Therefore you don't need to change it.
2) Press [Connection Setting...] button to configure the
communication settings.
3) Press [Write] button.
4) Press [Read] button, and confirm that the model name is
displayed in the Read Data field.
* When the model name is changed, turn OFF and ON before
saving the log and setting to the USB flash drive, restoring the
settings from USB flash drive or updating the firmware.
Until turning OFF and On the main power, this function access to
the previous model name folder.
10-4. MODEL NAME CHECK METHOD
Press [Display] button on the remote controller to indicate the
display information, and check the model name.