Sharp PN-L803C Service Manual page 104

Touch display / touch pen
Hide thumbs Also See for PN-L803C:
Table of Contents

Advertisement

Figures 1
<CONNECTION OF INSTRUMENTS AND IDP>
Back view of PN-L803C/80TC3
AC inlet
T-CON
PWB
<CHECKING CONNECTION BETWEEN C-PWB AND FFC/LVDS>
- Connect straightly and completely.
- Connector of FFC has holding mechanism. Holding part must not be loose.
EXAMPLES OF IMPORER STATE
Figures 2
<CONNECTION OF INSTRUMENTS AND IDP>
1 ) Display flicker pattern with service tool.
2 ) Change the value roughly from min. to max. (with [UP] or [DOWN] button) and watch display.
3 ) Degree of flicker changes as the value change.
4 ) Search approximate value which flicker is least at center of the display (with [UP] or [DOWN] button).
5 ) In addition to above, Search value which flicker is least at the center of the display (with [UP] or [DOWN] button) in detail.
PN-L803C/80TC3 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 38
LVDS harness
MAIN
PWB
LAN cable
FFC
FIGURE SHOWS REGION TO OBSERVE
FLICKER WITH RED CIRCLE
PC
DISPLAY
Observe flicker
near center.