ISSUE 4.0
Boxes or Security Sensor devices. A maximum two Doorphone Boxes or Security Sensor devices can
be connected per 082U-B1.
5.5.1
Wall-Mounting the Doorphone
1.
Remove the screw on the front of the Doorphone Box.
2.
Remove the Wall-Mount bracket from the Doorphone Box.
3.
Connect the cable to the screw terminals on the Doorphone box. (No polarity sensitive)
4.
Mount the Wall-Mount bracket on the wall using supplied screws.
5.
Replace the Upper housing and tighten the screw.
5.5.2
Connecting the Doorphone/External Sensor Device
The Doorphone Box/Security Sensor device configuration is assigned using by hardware switch
setting on the 082U-B1.
INSTALLING THE MULTILINE TELEPHONES AND OPTIONAL TERMINALS
Figure 2-108 Doorphone Box and Bracket
Figure 2-109 Doorphone
SL2100