Ground Requirement
Feeding Voltage
AC Input I
KWh
BTU (KWh x 3413)
1.8.3
AC Power Cord
The AC power switch and AC power inlet are located at the back side of each Chassis. The AC power
cord is connected to the AC inlet and the commercial AC power socket.
Before connecting the AC power cord, make sure:
• The power switch at the back side of each Chassis is turned OFF.
• The power switch at the commercial AC power socket is turned OFF.
• The AC plug fits the commercial AC power socket. The plug adapter is necessary if it
does not fit.
• To prevent damage, do not use a hammer to connect the AC power cord to AC power
jack on the chassis, it must be connected by hand.
To Commercial
AC Power Socket
INSTALLING THE MAIN & EXPANSION CHASSIS
110VAC
120VAC
Main Chassis =
Main Chassis =
1.43 A
1.25 A
3 Chassis Total
3 Chassis Total
= 4.29 A
= 3.75 A
Main Chassis =
Main Chassis =
0.143 KWh
0.150 KWh
3 Chassis Total
3 Chassis Total
=0.429 KWh
=0.450 KWh
Main Chassis =
Main Chassis =
488 BTU
512 BTU
3 Chassis Total
3 Chassis Total
=1464 BTU
=1536 BTU
Connect
AC Power Cord
Figure 2-26 AC Power Cord
220VAC
230VAC
No.14 AWG Copper Wire
SLT: 20 mA/ -27 V
Main Chassis =
Main Chassis =
0.82 A
0.79 A
3 Chassis Total
3 Chassis Total
= 2.46 A
= 2.37 A
Main Chassis =
Main Chassis =
0.185 KWh
0.182 KWh
3 Chassis Total
3 Chassis Total
=0.541 KWh
=0.545 KWh
Main Chassis =
Main Chassis =
631 BTU
621 BTU
3 Chassis Total
3 Chassis Total
=1894 BTU
=1863 BTU
SL2100
240VAC
Main Chassis =
0.76 A
3 Chassis Total
= 2.28 A
Main Chassis =
0.182 KWh
3 Chassis Total
=0.547 KWh
Main Chassis =
621 BTU
3 Chassis Total
=1863 BTU
Chassis
57