ISSUE 4.0
Frequency
Phase and Wire
Ground Requirement
Feeding Voltage
AC Input I
KWh
BTU(KWh x 3413)
2.6 Electrical Specifications <Power Supply> (Chassis)
Item
Output Voltage
Output Current
2.7 CPU
CONTROL SYSTEM
MPU
PROGRAM STORAGE
DATA STORAGE
SWITCHING (Time Division Matrix)
2.8 Traffic Capacity
Traffic Capacity
Traffic Capacity
2540 Busy-Hour Call Attempts (BHCA) is based on a Full Capacity.
SYSTEM SPECIFICATIONS
110VAC
Main Chassis =
Main Chassis =
1.43 A
1.25 A
3 Chassis Total
3 Chassis Total
= 4.29 A
= 3.75 A
Main Chassis =
Main Chassis =
0.143 KWh
0.150 KWh
3 Chassis Total
3 Chassis Total
=0.429 KWh
=0.450 KWh
Main Chassis =
Main Chassis =
488 BTU
512 BTU
3 Chassis Total
3 Chassis Total
=1464 BTU
=1536 BTU
Table 5-4 Electrical Specifications of Chassis
SL2100
Manufacturer/ Name
MPU Architecture
Core Frequency
Nand Flash
SDRAM
Basic System Package
2540 BHCA
120VAC
220VAC
47 Hz - 63 Hz (Rated Frequency: 50/60 Hz)
Single Phase, 2 Line + PE Type
No.14 AWG Copper Wire
SLT: 20 mA/-27 V
Main Chassis =
0.82 A
3 Chassis Total
= 2.46 A
Main Chassis =
0.185 KWh
3 Chassis Total
=0.541 KWh
Main Chassis =
631 BTU
3 Chassis Total
=1894 BTU
Specification
-27 V (54 W)
2.0 A
Digital
HITACHI
OPV5HB-23-C
Cortex-A9 (3core) 32-bit RISC based processor
800 MHz
256 MB
128 MB x 2
402 x 402 (Non-Blocking)
Expanded System Package
SL2100
230VAC
240VAC
Main Chassis =
Main Chassis =
0.79 A
0.76 A
3 Chassis Total
3 Chassis Total
= 2.37 A
= 2.28 A
Main Chassis =
Main Chassis =
0.182 KWh
0.182 KWh
3 Chassis Total
3 Chassis Total
=0.545 KWh
=0.547 KWh
Main Chassis =
Main Chassis =
621 BTU
621 BTU
3 Chassis Total
3 Chassis Total
=1863 BTU
=1863 BTU
2540 BHCA