6 T e c h n i c a l D e s c r i p t i o n
Image Screen Display
Patient Registration
Form
Text Annotation
Pictograms
6 - 2 4
Arranged by Image, Calcs, Review, and Compose task cards
Additional screens to support filming (printing), reports, patient browser, system
presets, online help, and the patient registration form
Recordable image area of 800 by 600 pixels
Centimeter (cm) scale marker with depth of display, focal zones: number and
position, gray bar, color bar, transducer orientation indicator, error and help
messages. Parameter menu indicating the priority mode. The menu lists values,
settings, and controls for the imaging parameters of the priority mode: Transmit
Power, Gain, and Maps (all modes).
2D-mode: Dynamic Range, Resolution/Speed, Edge Enhancement,
Persistence, Tint
Color: PRF, Flow, Invert, Tissue Reject, Wall Filter, Resolution/Speed, Baseline,
Persistence, Smoothing, Display Color
Power: PRF, Flow, Background, Tissue Reject, Wall Filter, Reslution/Speed,
Persistence, Smoothing, and Display Power
Doppler: PRF, Baseline, Invert, Coarse Angle Correction, Wall Filter, Gate Size,
Sweep, Steer Reverse, Dynamic Range, Tint and Time/Frequency Resolution
Parameter menu selections for the following options: SieClear, TEQ, Clarify VE,
and CCAI
Active transducer and transmit frequency, exam type, active measurement
method, Measurement Label menu, Measured Results
Controls in "group boxes" for imaging formats and mixed-mode updates styles,
SieScape (option), 3-Scape (option), on-screen Biopsy guidelines, VCR recording
(option), Extend (option), and Physio settings (option)
Trackball status icons and print/store icons
Fields for names of the patient, patient identification, patient information (date of
birth, age, sex, height, weight, blood pressure), institution, performing and
referring physician, and operator's initials
System-defined and user-defined text for each application. User can directly enter
text on the image screen using the keyboard. Auto-complete text provides
matching phrases to entered character(s); Text A, B, C or D keys insert pre-defined
text on the screen
Standard and exam-specific graphics representing anatomical structures are user
selectable. Transducer position and orientation are also available for positioning on
the pictograms