Installation and operation manual
Illustration
CAUTION
Disassembly work
Lifting heavy loads!
Lifting the full filter cartridge in an ergonomically incorrect manner can result in
personal injury.
Lift the full cartridge in an ergonomically correct manner close to your body.
Use two people to lift the full cartridge over obstacles.
3 sec
Description / explanation
6. Turn the bayonet catch of the filter cartridges 
anticlockwise and pull it off the connection at 
the measuring chamber outlet.
7. Starting with the last filter cartridge in the 
front row, turn the filter cartridges 45 degrees 
anticlockwise and seal them with the plugs
provided.
8. Lift the filter cartridge out of the collector and 
dispose of it properly (see section "14. Disposal"
on page 113).
9. Switch off FRC
0 Press and hold down the ON/OFF button for
3 seconds.
0 The FRC switches to standby mode.
0 All LEDs go out and the status LED STATUS
BAR flashes white at regular intervals.
10. Cut off the compressed air supply and lock and 
tag it out so that it cannot be opened again.
11. Carefully depressurise the compressed air hose
at the compressed air connection [D].
QWIK-PURE
®
109 | 124