QWIK-PURE
®
10.3.3 Replacing solenoid valves
INFORMATION Cancel operating action.
i
Tools
•
Allen key, 2.5 mm
1.
Provide the required SOLENOID VALVES Service-Unit.
Illustration
2 x
3 sec
90 | 124
Actions can be cancelled at any time by pressing the Start Menu button. Any
changes made are not saved when you cancel.
Prerequisites
•
SOLENOID VALVES Service-Unit
•
Absorbent materials
Preparatory tasks
Material
Description / explanation
1. Press the menu button twice.
The current status of the solenoid valves is
displayed.
0 The status LED SOLENOID VALVES flashes
red.
0 The status LED STATUS BAR lights up red.
2. Press and hold the Service button for 3 seconds.
Installation and operation manual
Protective equipment
Always to be worn: