16. After replacing the filter cartridges, press and 
hold down the Enter button for 3 seconds.
0 The piston in the FRC will open the
condensate inlet from the pressure relief
chamber into the FRC.
3 sec
0 The status LED STATUS BAR lights up green.
0 The display will switch to the START MENU
screen.
17. Remove the cover from the pressure relief
chamber and remove the activated carbon mat
from the vent of the pressure relief chamber.
0 Check the activated carbon mat for heavy
soiling (e.g. mould, oil saturation, etc.) and 
replace it if necessary.
18. Fill the QWIK‑PURE
vent.
0 Stop filling as soon as the FRC performs a
discharge operation.
19. Insert the activated carbon mat into the vent of
the pressure relief chamber and place the cover
on the pressure relief chamber.
20. Slowly open the condensate feed.
21. Check all hoses and connections for leaks (see 
section "10.3.7 Leakage test" on page 100).