Figure 148. Sliding the node halfway into the chassis
3. Pull the black release tab out completely, and slide the rest of the node back into the chassis.
The black release tab slides back into the system as it is inserted.
Figure 149. Installing the node
4. Reconnect the back-end cables and the cables to the I/O modules and network ports.
5. Pull the orange release trigger and push in gently to re-engage the locking mechanism.
If the black release tab comes out when pulled, the locking mechanism is not engaged.
6. Plug in the power cable.

Verify the operation of a replacement node

Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance where you replaced the node.
3. On the Components card, under Rear View, expand BaseEnclosure.
4. Select the relevant Node.
The status of the replacement node should read Healthy. If the status is still Faulted, wait a few minutes and refresh
PowerStore Manager. If the status does not change, ensure that the node is correctly seated, or contact your service
provider.