Power Down The Node; Remove A Faulted Embedded Module - Dell PowerStore 1000 Installation And Service Manual

Table of Contents

Advertisement

Table 4. Embedded module LEDs (continued)
LED
Node power
Node fault
Port link
Ethernet port activity
Ethernet port link
2-port 100GbE card port link
Embedded module fault
2-port 100GbE card port activity

Power down the node

Power down the node as described in

Remove a faulted embedded module

Steps
1. Label and disconnect all cables that are attached to the embedded module.
CAUTION:
Do not pull the node from the base enclosure. Pulling the node from the base enclosure disrupts
the system cache.
2. Push the orange tab on the embedded module to release the lever.
Location
Power control
procedures.
State
Description
Off
Safe to remove the node when the node
has been properly prepared.
Green
Node is on (main power).
Green blinking
Node is initializing a serial over LAN
session.
Off
Node is off.
Amber
Fault has occurred.
Blue
Node in Degraded Mode.
Amber or blue
System is booting.
blinking
Blue and amber
System uninitialized. A management IP
alternating (green
address has not been assigned.
for 3 seconds)
Blue and amber
Node in Service Mode.
alternating at one
second intervals
Green
Link up with high speed.
Amber
Link up with degraded speed.
Off
Link down.
Amber blinking
Port activity.
Off
No port activity.
Green
Link established.
Off
No link established.
Green
Link established.
Off
No link established.
Amber
Embedded module has faulted.
Off
No fault has occurred, normal operation.
Green blinking
Port activity.
Off
No port activity.
Base enclosure service procedures
63

Advertisement

Table of Contents
loading

Table of Contents