Verify The Operation Of A Replacement Fan Module - Dell PowerStore 1000 Installation And Service Manual

Table of Contents

Advertisement

Figure 101. Sliding the node halfway into the chassis
3. Pull the black release tab out completely, and slide the rest of the node back into the chassis.
The black release tab slides back into the system as it is inserted.
Figure 102. Installing the node
4. Reconnect the back-end cables and the cables to the I/O modules and network ports.
5. Pull the orange release trigger and push in gently to re-engage the locking mechanism.
If the black release tab comes out when pulled, the locking mechanism is not engaged.
6. Plug in the power cable.

Verify the operation of a replacement fan module

Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance where you replaced the fan module.
3. On the Components card, under Internal View, expand the node that includes the fan module, and then select the relevant
FanModule.
The status of the replacement fan module should read Healthy. If the status is still Faulted, wait a few minutes and
refresh PowerStore Manager. If the status does not change, ensure that the fan module is correctly seated, or contact your
service provider.
92
Base enclosure service procedures