Communication - Hitachi Relion 670 Series Applications Manual

Hide thumbs Also See for Relion 670 Series:
Table of Contents

Advertisement

1MRK506375-UEN Rev. N
2.5

Communication

IEC 61850 or function
ANSI
name
Station communication
LONSPA, SPA
ADE
HORZCOMM
PROTOCOL
RS485PROT
RS485GEN
DNPGEN
CHSERRS485
CH1TCP, CH2TCP,
CH3TCP, CH4TCP
CHSEROPT
MSTSER
MST1TCP, MST2TCP,
MST3TCP, MST4TCP
DNPFREC
IEC 61850-8-1
GOOSEINTLKRCV
IEC 61850SIM
GOOSEBINRCV
GOOSEDPRCV
GOOSEINTRCV
GOOSEMVRCV
GOOSESPRCV
ALGOS
MULTICMDRCV,
MULTICMDSND
OPTICAL103
RS485103
AGSAL
LD0LLN0
SYSLLN0
LPHD
PCMACCS
SECALARM
FSTACCSNA
FSTACCS
GOOSEACRCV
ACTIVLOG
ALTRK
PRP
HSR
RSTP
Table continues on next page
Railway application RER670
Application manual
Function description
SPA communication protocol
LON communication protocol
Network variables via LON
Operation selection between SPA and IEC 60870-5-103 for SLM
Operation selection for RS485
RS485
DNP3.0 communication general protocol
DNP3.0 for EIA-485 communication protocol
DNP3.0 for TCP/IP communication protocol
DNP3.0 for TCP/IP and EIA-485 communication protocol
DNP3.0 serial master
DNP3.0 for TCP/IP communication protocol
DNP3.0 fault records for TCP/IP and EIA-485 communication protocol
IEC 61850
Horizontal communication via GOOSE for interlocking
IEC 61850 simulation mode
GOOSE binary receive
GOOSE function block to receive a double point value
GOOSE function block to receive an integer value
GOOSE function block to receive a measurand value
GOOSE function block to receive a single point value
Supervision of GOOSE subscription
Multiple command receive and send
IEC 60870-5-103 Optical serial communication
IEC 60870-5-103 serial communication for RS485
Generic security application component
IEC 61850 LD0 LLN0
IEC 61850 SYS LLN0
Physical device information
IED configuration protocol
Component for mapping security events on protocols such as DNP3 and IEC103
Field service tool access via SPA protocol over Ethernet communication
Field service tool access
GOOSE function block to receive a protection activation information
IEC 61850-9-2 Process bus communication, 12 merging units
Activity logging
Service tracking
IEC 62439-3 Parallel redundancy protocol
IEC 62439-3 High-availability seamless redundancy
IEC 62439-3 Rapid spanning tree protocol
© 2017 - 2023 Hitachi Energy. All rights reserved
Section 2
Application
GUID-C1FB7B84-2F43-4F15-9264-F33832C8036B v2
Railway
RER670
1
1
1
1
1
1
1
1
1
1
1
1
1
1
59
1
11
40
24
72
40
100
60/10
1
1
1
1
1
1
1
1
1
1
16
1-P30
1
1
1-P23
1-P24
1-P25
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Relion rer670

Table of Contents