5 DATA USED FOR POSITIONING CONTROL
Setting Value, setting range
Value set with peripheral device
Servo amplifier setting invalid
(
: Valid,
: Invalid)
MR-J3-B
2: The PB
corresponds with servo parameter No. of the servo amplifier.
3: Set the parameter value and switch power off once (The parameter is transferred to servo amplifier from QD75MH), then switch it
on again to make that parameter setting valid.
Value set with PLC program
0
H
Machine resonance
suppression filter 2
Notch depth selection
Notch width selection
1:
is used to set up the setting
value. (Hexadecimal)
100 to 18000
1 to 1000
1 to 1000
5 - 75
MELSEC-Q
Setting value buffer memory
address
Default
value
Axis 1 Axis 2 Axis 3 Axis 4
0000
30134 30334 30534 30734
H
3141
30136 30336 30536 30736
1000
30137 30337 30537 30737
1000
30138 30338 30538 30738