3 SPECIFICATIONS AND FUNCTIONS

3.4.3 List of input signal details

Signal name
Manual pulse generator A
phase
Manual pulse generator B
phase
Manual pulse generator A
common
Manual pulse generator B
common
Upper limit signal
Lower limit signal
Near-point dog signal
Stop signal
External command signal/
switching signal
Common
Forced stop input signal
Forced stop input signal
common
Manual pulse generator power
supply (+ 5VDC)
Manual pulse generator power
supply (GND)
The details of each QD75MH external device connection connector are shown below:
Pin No.
AX1 AX2 AX3 AX4
1A19
1A20
1B19
1B20
1A1
1B1
2A1
2B1
1A2
1B2
2A2
2B2
1A3
1B3
2A3
2B3
1A4
1B4
2A4
2B4
1A5
1B5
2A5
2B5
1A6
1B6
2A6
2B6
1A7
1B7
2A7
2B7
1A8
1B8
1A15
1B15
1A14
1B14
(Negative logic is selected by external input signal logic selection)
• Input the pulse signal from the manual pulse generator A phase and B
phase.
• If the A phase leads the B phase, the positioning address will increase at the
rising and falling edges of each phase.
• If the B phase leads the A phase, the positioning address will decrease at the
rising and falling edges of each phase.
[When increased]
A phase
B phase
Positioning
+1+1+1+1+1+1+1+1
address
• This signal is input from the limit switch installed at the upper limit position of
the stroke.
• Positioning will stop when this signal turns OFF.
• When OPR retry function is valid, this will be the upper limit for finding the
near-point dog signal.
• This signal is input from the limit switch installed at the lower limit position of
the stroke.
• Positioning will stop when this signal turns OFF.
• When OPR retry function is valid, this will be the lower limit for finding the
near-point dog signal.
• This signal is used for detecting the near-point dog during OPR.
• The near-point dog OFF
• The near-point dog ON
• Input this signal to stop positioning.
• When this signal turns ON, the QD75MH will stop the positioning being
executed.
After that, even if this signal is turned from ON to OFF, the system will not
start.
• Input a control switching signal during speed-position or position-speed
switching control.
• Use this signal as the input signal of positioning start, speed change request,
and skip request from an external device.
Set the function to use this signal in "
selection".
• Common for upper/lower limit, near-point dog, stop, and external command
signal/switching signals.
• This signal is input when batch forced stop is available for all axes of servo
amplifier.
• When this signal turns OFF, the QD75MH will be the forced stop.
• Power supply for manual pulse generator. (+ 5VDC)
• Power supply for manual pulse generator. (GND)
3 - 20
Signal details
[When decreased]
A phase
B phase
Positioning
-1 -1 -1 -1 -1 -1 -1 -1
address
ON is detected at the rising edge.
OFF is detected at the falling edge.
Pr.42
External command function
MELSEC-Q