Mitsubishi Electric MELSEC-QD75MH1 User Manual page 599

Positioning module
Table of Contents

Advertisement

12 CONTROL SUB FUNCTIONS
QD75MH
[4] When the hardware stroke limit function is not used
When not using the hardware stroke limit function, wire the terminals of the
QD75MH upper/lower limit stroke limit as shown in the following drawing.
When the logic of FLS and RLS is set to "positive logic" using "
signal logic selection", positioning control can be carried out even if FLS and RLS
are not wired. (For details, refer to Section 13.4 "External I/O signal logic
switching function".)
FLS
RLS
COM
24VDC
Fig. 12.20 Wiring when not using the hardware stroke limit function
(When "
Pr.22
Input signal logic selection" is the initial value)
MR-J3-B
12 - 38
MELSEC-Q
Pr.22
DI1
(FLS)
DI2
(RLS)
DICOM
24VDC
Input

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-q seriesMelsec-qd75mh2Melsec-qd75mh4

Table of Contents