Mitsubishi Electric MELSEC-QD75MH1 User Manual page 604

Positioning module
Table of Contents

Advertisement

12 CONTROL SUB FUNCTIONS
Md. 40 In speed change processing flag
Cd. 14 New speed value
Designated speed in P2
Designated speed in P1
[1] Control details
The following drawing shows the operation during a speed change.
V
Fig. 12.23 Speed change operation
[2] Precautions during control
(1) Control is carried out as follows at the speed change during continuous path
control.
a) When no speed designation (current speed) is provided in the next
positioning data:
The next positioning data is controlled at the "
value".
b) When a speed designation is provided in the next positioning data:
The next positioning data is controlled at its command speed
(
Da.8
Positioning control
Fig. 12.24 Speed change during continuous path control
(2) When changing the speed during continuous path control, the speed change
will be ignored if there is not enough distance remaining to carry out the
change.
Speed changes to V2.
Speed changes to V3.
V1
V2
).
Next control
P1
Speed change
command
12 - 43
MELSEC-Q
Operation during
positioning by V1.
V3
t
Cd.14
New speed
P2
[a] When no speed designation
(current speed) is provided.
[b] When a speed designation
is provided.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-q seriesMelsec-qd75mh2Melsec-qd75mh4

Table of Contents