Mitsubishi Electric MELSEC-QD75MH1 User Manual page 236

Positioning module
Table of Contents

Advertisement

5 DATA USED FOR POSITIONING CONTROL
Monitoring is carried out with a hexadecimal display.
0
b15
b12
b8
Buffer
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
memory
Not used
Not used
Monitoring is carried out with a decimal display.
Monitor
R
value
Unit conversion
Actual
Target value
Md.32
value
Reading the monitor value
Monitor
value
b4
b0
Stored items
b0
In speed control flag
b1
Speed-position switching latch flag
b2
Command in-position flag
b3
OPR request flag
b4
OPR complete flag
b5
Position-speed switching latch flag
b9
Axis warning detection
b10
Speed change 0 flag
Decimal integer
value
n
R
10
Default
Meaning
value
0
0
0
0: OFF
0
1: ON
0
0
0
0
Unit conversion table
)
Md.32
n
Unit
m
-1
inch
-5
degree
-5
PLS
0
5 - 135
MELSEC-Q
Storage buffer
Default
memory address
value
Axis 1 Axis 2 Axis 3 Axis 4
0000
817
917
1017 1117
H
818
918
1018
0
819
919
1019
1118
1119

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-q seriesMelsec-qd75mh2Melsec-qd75mh4