2-1. INTRODUCTION.
2-2. This section contains instructions for installing and interfacing the Model 3336A/B/C
Synthesizer/Level Generator. Included are initial inspection procedures, power and groun-
ding requirements, line voltage selection, environmental requirements, installation instruc-
tions, HP-IB connection procedure, and instructions for repackaging for shipment.
2-3. INITIAL INSPECTION.
2-4. Inspect the shipping container for damage. If the shipping container or cushioning
material is damaged, it should be kept until the contents of the shipment have been checked
for completeness and the instrument has been checked mechanically and electrically. This in-
strument was carefully inspected both mechanically and electrically before shipment. It
should be free of mars and scratches and in perfect electrical order upon receipt. Procedures
for checking electrical performance are given in Section IV. If there is mechanical damage or
defect or if the instrument does not pass the electrical performance test, notify the nearest
Hewlett-Packard Sales and Service Office listed at the end of this manual. If the shipping
container is damaged or the cushioning material shows signs of stress, notify the carrier as
&
well as the Hewlett-Packard office. Keep the shipping material for the carrier's inspection.
The warranty statement is located in the front of this manual.
2-5. PREPARATION FOR USE.
2-6. Power Requirements.
2-7. The Model 3336 requires a power source of 100, 120, 220, or 240 V ac,
+5%, —10%,
48 to 66 Hz single phase. Power consumption is 100 VA maximum.
Before connecting ac power to this instrument,
make sure the
Model 3336 is set to the line voltage of the power source. Also en-
sure that the common connection of the power outlet is connected
to a protective earth contact.
2-8. Line Voltage Selection.
2-9. The line voltage selection switches are set at the factory to correspond to the most com-
monly used line voltage of the country of destination. The serial number plate (located on
the rear panel) is marked at the factory to indicate the selected line voltage. To reduce confu-
sion, update this plate every time the line voltage switches are changed.
Information
necessary to change the line voltage selection is in the Power Supply PERNICE Group of the
&
Operating and Service Manual.