HP 3336A Operating Manual page 92

Synthesizer/level generator
Hide thumbs Also See for 3336A:
Table of Contents

Advertisement

Model 3336A/B/C
Electronic Counter
Digitai Voltmeter
Wave Analyzer
Synthesizer
Unbalanced
Directional
Couplers
*Unbalanced
Directional Couplers are also part of Transmission/Reflection kits:
-hp- Model
11652A
-hp- Model
11652A with Option 008
50 2 Transmission/Reflection
Kit
75 Q Transmission/Reflection
Kit
Performance Tests
Table 4-2. Recommended Test Equipment
INSTRUMENT
CRITICAL SPECIFICATION
REQUIRED FOR
RECOMMENDED MODEL
Frequency Measurements
Range:
to 20.9 MHz
Resolution:
8 digits
Accuracy:
+1 part/109
Time Interval Average
Resolution:
.1 ns
dc Function
Ranges:
.1V, 1V, 10V, 100V
Accuracy:
+ .2%
Resolution:
4% digits
ac Function
Ranges:
1V, 10V, 100V
Accuracy:
+ .5%
Resolution:
4 digits
dc function
Ranges:
.1V, 1V, 10V, 100V
Accuracy:
+ .05%
Resolution:
6 digits
ac Function
Ranges:
1V, 10V, 100V
Accuracy:
+ .15% at 10 and
50 kHz
Resolution:
5 digits
Frequency
Range:
15
Hz
to
50 kHz
Amplitude Accuracy:
+ .5 dB
Spurious Response:
< — 80dBc
Y-Axis output
Frequency
Range:
200
Hz
to
20.9 MHz
Amplitude
Range:
—60
to
+13 dBm
Phase
Noise:
<
70
dBc
@
20MHz
Spurious:
<
—75 dBc
50 ohm
Srequency Range:
.1 to
20.9 MHz
Directivity:
= 40 dB
75 ohm
Frequency Range:
.1 to
20.9 MHz
Directivity:
= 40 dB
V = Oper. Ver.
P = Performance Test
T = Troubleshooting
A = Adjustments
V,P,A
-hp- Model
5328A
with Options 010 and
040 or 041
T
-hp- Model 3466A or
-hp- Model 3455A
w/Option 001
V,P,A
-hp- Model 3455A with Option 001
(Average Responding Converter)
or -hp- Model 3490A
V,P,A
-hp- Model 3581A or 3581C
P
-hp- Model 3335A
{-hp- Model 3325A
is acceptable except for
Phase Noise and Spurious Performance Tests)
P (3336C only)
-hp- Model 8721A*
P (all models)
-hp- Model 8721A*
with Option 008

Advertisement