HP 3336A Operating Manual page 26

Synthesizer/level generator
Hide thumbs Also See for 3336A:
Table of Contents

Advertisement

Model 3336A/B/C
Operation
3-13. The Model 3336 is manufactured as one of three models identified by the letters A, B
@
or C following the model number. The difference between models is the configuration of the
front panel outputs. The outputs on each model are:
Model
Outputs
Accepts Connector Type
3336A
75 ohm unbal
75 ohm BNC
150 ohm bal
Siemens type REL
STP—6AC
600 ohm bal
Siemens type V9REL
STP—6AC
3336A with
75 ohm unbal
Siemens type 1.6/5mm coaxial
Option 001
150 ohm bal
Siemens type SQREL
STP—6AC
600 ohm bal
Siemens type QREL
STP—6AC
3336B
75 ohm unbal
WECO type 439A or 440A
124 ohm bal
WECO type 443A
135 ohm bal
WECO type 241A
600 ohm bal
WECO type 310
3336B with
75 ohm unbal
WECO type 358A
Option 001
124 ohm bal
WECO type 372A
135 ohm bal
WECO type 241A
600 ohm bal
WECO type 310
3336C
50 ohm unbal
50 ohm BNC
@
75 ohm unbal
75 ohm BNC
3-14. Frequency Limits.
3-15. It is possible to enter frequencies from 10 Hz to 20.999 999 999 MHz for any front
panel output. The instrument specifications, however, apply only during operation within
the following frequency limits:
Output
Lower Frequency Limit
Upper Frequency Limit
50 ohm unbal
20.9 MHz
75 ohm unbal
20.9 MHz
124 ohm bal
10.9 MHz
135 ohm bal
2.09 MHz
150 ohm bal
2.09 MHz
600 ohm bal
109 kHz
3-16. Frequency Resolution.
3-17. The frequency resolution for all outputs with programmable frequencies is:
-
1 »Hz for frequencies below 100 kHz.
1 mHz for frequencies 100 kHz and above.
3-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

3336b3336c

Table of Contents