3.5.3
Removing the Switch PCB Assy
1. Remove the eight Switch PCB screws from under the Body cover. Remove the
Switch PCB assy.
2. Remove the Start key, Stop key, Two-connection switch, Continuous key, and Extra
border key.
The LED lenses can be removed from the Top cover by pushing them hard with a
fine object such as a pen tip.
LED lenses
Switch PCB assy
Switch PCB screws
Fig. 3.5-3
Removing the Switch PCB Assy 1
Extra border key
Two-connection switch
Fig. 3.5-4
Removing the Switch PCB Assy 2
LED lens
Stop key
Continuous key
3-17
Switch PCB screws
Start key