3.9 Roller Holder Assy
3.9.1
Removing the Roller Holder Assy
1. Lift up the Roller holder unit and disconnect the Roller holder return spring.
2. Remove the four Retaining rings (two from the Roller holder, two from the Paper
feed holder), then remove the Roller holder unit.
3. Remove the plastic spacer from the rivet pins at each end of the Roller holder assy.
Retaining rings
Spacer
Fig. 3.9-1
Removing the Roller Holder Assy
3-23
Roller holder return spring
Roller holder unit
Retaining rings
Spacer