NEC Express5800/R120b-1 User Manual page 310

Express5800/r120b-1
Table of Contents

Advertisement

8-14 Troubleshooting
Displayed Error Message
AE83
CPU1_DIMM3 with error
enabled.
CPU2_DIMM1 with error
AE87
enabled.
AE88
CPU2_DIMM2 with error
enabled.
AE89
CPU2_DIMM3 with error
enabled.
B000
DXE_LEGACY_OPROM_
NO_SPACE
Expansion ROM not
B001
initialized - PCI Slot 1B
B004
Expansion ROM not
initialized - PCI Slot 1C
B030
PCI System Error on
Bus/Device/Function
B040
PCI Parity Error on
Bus/Device/Function
C010
The error occurred during
temperature sensor
reading
System Temperature out of
C011
the range.
C020
The error occurred during
voltage sensor reading.
Description
CPU1_DIMM3 was disabled,
but, because all memory is
currently disabled, this DIMM
was forcibly enabled.
CPU2_DIMM1 was disabled,
but, because all memory is
currently disabled, this DIMM
was forcibly enabled.
CPU2_DIMM2 was disabled,
but, because all memory is
currently disabled, this DIMM
was forcibly enabled.
CPU2_DIMM3 was disabled,
but, because all memory is
currently disabled, this DIMM
was forcibly enabled.
There is no space for expanding
option ROM.
Option ROM expansion in PCI
slot 1B failed.
Option ROM expansion in PCI
slot 1C failed.
PCI SERR was detected.
PCI PERR was detected.
An error was detected while
reading the temperature sensor.
A temperature abnormality was
detected.
An error was detected while
reading the voltage sensor.
Recommended Action
Contact your service
representative.
If the board is not used
as a boot device,
disable the Option
ROM Scan for that
board.
Contact your service
representative.
It is possible that a fan
has failed or is clogged
up. Contact your
service representative
and request repairs.
Contact your service
representative.

Advertisement

Table of Contents
loading

Table of Contents