9-30 Upgrading Your Server
Installation
Install a DIMM in the following procedure.
IMPORTANT:
type (30 mm (1.2 inches) in height). It does not support DIMMs
exceeding the specified height.
1.
See page 9-4 to prepare.
2.
Pull out the server from the rack (as described on page 9-4).
3.
Remove the top cover (as described on page 9-24).
4.
Locate the DIMM socket which you are going to install DIMM.
5.
Make sure the clips at either end of the DIMM socket(s) are pushed outward to the open
position.
6.
Open levers at left and right side of the DIMM socket, and remove the dummy memory.
IMPORTANT:
7.
Holding the DIMM by the edges, remove it from its anti-static package.
8.
Position the DIMM above the socket. Align the small notch at the bottom edge of the
DIMM with the key in the socket.
NOTE:
Position the DIMM so that a notch in the bottom edge of the DIMM
aligns with the keyed socket. Applying too much pressure can damage
the socket. Keyed DIMMs insert only one way.
9.
Insert the bottom edge of the DIMM into the socket.
10.
When the DIMM is inserted, push down on the top edge of the DIMM until the retaining
clips snap into place.
The server supports DIMMs of only the low-profile
Keep the removed dummy memory for future use.
Make sure of the orientation of the DIMM.
Key slot
Key