LAN Monitoring Threshold
Because the NEC Express5800/ft series detects hardware faults on the network in the driver level,
NEC ESMPRO Agent does not monitor line faults. Thus, the value set for "Line fault occurrence
rate" of a [LAN] tab of [NEC ESMPRO Agent properties] in the control panel is not used.
Hardware Monitoring by ESMPRO
In NEC Express5800/R320a-E4/ R320b-M4, an alert report is not issued if an error on power supply
is detected in CPU module and PCI module.
Moreover, the trees [Power Supply] is not displayed on [System Environment] of DataViewer of
NEC ESMPRO Manager.
As the characteristic of ft server, there are cases that recovery events of temperature, fan and electric
voltage may not occur when CPU/IO module is isolated. However, you can confirm the recovery by
checking the sensor status.
If the already installed CPU/IO module is isolated, the sensor status is displayed as normal, and the
sensor status is reacquired when CPU/IO module is mounted again.
System Environment Monitoring
On NEC Express5800/320Fd-MR, monitoring of temperature, fan and voltage under [System
Environment] of [ESMPRO] tree in the DataViewer is set to enable and cannot be changed to
disable by default.
Change Settings of File System Monitoring Function
New settings in thresholds of monitoring interval and free space monitoring are not reflected
immediately after they are changed. They are reflected at the next monitoring interval of monitoring
service.
Temperature/voltage error occurs on the CPU/PCI modules
At the time when a temperature or voltage error occurs on CPU/PCI module
(CPU/IO module), necessary actions will differ depending on their status as
shown below. You can check the status of each module from the DataViewer of NEC ESMPRO
Manager or ftServer Utility.
Status
Duplex
Simplex
-
If the status is "Empty", the module is not mounted. Sensor monitoring is not conducted.
-
If disks are mounted on PCI modules (IO modules), the status of both modules is "Simplex"
Stop the failed CPU/PCI module (CPU/IO module).
Shut down the system.
Installing and Using Utilities 5-39