3-6 Windows Setup and Operation
TIPS:
Specify disks to correspond on the RDR Utility screen.
The correspondence of disk number displayed on [Disk Management] and the drive
letters may change when the system is restarted.
[Right pane]
The properties of the disk selected in the left pane are shown.
In the figure above, the properties of the disk inserted to the Slot 1 of the PCI module 10.
IMPORTANT:
The [RDR Utility] display is not updated automatically. Therefore, update it by clicking
[Refresh] from [Action] on the menu or pressing F5 after performing operations to disk
such as inserting/removing a disk, specifying/removing the RDR setting.
Making disks duplex by RDR
The following describes the procedure to set duplex configuration to disks by RDR.
In this example, the disks of the Slot 1 of the PCI modules 10 and 11 are duplexed.
Insert a new disk to a built-in slot.
1.
(In this example, a disk is inserted to the Slot 1 of the PCI module 10.)
From [Start], select [Administrative Tools]
2.
and start [Computer Management]. On the
tree in the left pane, click [Disk
Management].
If the inserted disk is indicated as [Not
Initialized] in the right pane, right-click the
disk and initialize it.
IMPORTANT:
When a disk is inserted or initialized, a
popup window asking for rebooting the
system may be displayed, but there is no
need to reboot it. Select [Restart Later]
and close the popup window.