Event log which warn CPU load monitoring is registered:
→ If NEC ESMPRO Agent cannot get performance information from the OS due to a
temporary resource shortage or high load ratio on the system, it will record the
following event log. However, there is no real problem on operation. (In the
description, Y and X represent alphanumeric characters.)
Source:
Type:
Event ID:
Description: Cannot get system performance information now (YYYY
If NEC ESMPRO Agent cannot get information, it will treat the load ratio as 0%.
So, if NEC ESMPRO Agent cannot get information continuously, the CPU load
ratio may appear lower than the actual value.
[Detected past event] is recorded
→ Following event is recorded when MSCS is used, then the warning is sent to NEC
ESMPRO Manager
Source:
Event ID:
Description: Cannot get system performance information now (YYYY
- System time is modified.
- System was not shut down properly.
- Event log file is broken.
MSCS has a function which enables to see every event on the computer's cluster
configuration. In some cases, however, events are not stored by date, when such as
shutting down only one side, or launching only one side.
As NEC ESMPRO Agent checks whether the events are stored by date, any events
out of the date order is shown as "Past Event Detected."
Note that even when this event is recorded, the event log function continues to
function properly for the events stored by date.
ESMCpuPerf
Information
9005
Code=xxxx).
AlertManagerMainService
802
Code=xxxx).