10.2 Power Supply Lower Level

This function activates an auxiliary output port that is
assigned to a Power Supply Lower Limit function when a
voltage of power becomes lower than a configured level.
You can configure the reference voltage in order to
activate/deactivate an auxiliary output port.
Assigning Functions to the Auxiliary Output Ports.)
! Configuration of KPG-91D
" Configuring the Power Supply Lower Level (Refer
to FPRG 6.4.1 "Optional Features 1" tab.)

10.3 RX Signal Detect (Below)

This function activates an auxiliary output port that is
assigned to a RX Signal Detect function when the RSSI
voltage becomes lower than a configured level and the
port deactivates when the voltage level becomes higher
than the configured level. You can configure the reference
voltage to activate/deactivate the auxiliary output port.
(Refer to 20.3 Assigning Functions to the Auxiliary Output
Ports.)
Note: RSSI voltage is changed along with a strength of a reception
signal and it is used to detect the presence of carrier.
! Configuration of KPG-91D
" Configuring the RX Signal Detect function (Refer
to FPRG 6.4.1 "Optional Features 1" tab.)

10.4 DC Power Save

This function is one of the Save Mode functions reducing
consumption current of the TKR-750/850/751/851. With
this function, you can configure a duration to operate in
Save Mode and operations working in conjunction with
auxiliary ports and PF keys.
You can configure the following functions relating to Save
Mode by KPG-91D.

Save Delay Timer A

Save Delay Timer B

Save Mode Duration

Save On
Save Off
Note:
Version: 1.01 USA
# When TKR-750/850/751/851 receives a carrier while operating
in Save Mode, a wait time is added until it exits save mode.
# The illumination of PF [Save Mode On/Off] key remains switched
Off immediately after entering into Save Mode.
10.4.1 Save Delay Timer A
(Refer to 20.3
You can configure a duration between the time when an
Auxiliary Input port or a PF key assigned to the Display
On function receives a signal and the time when the LED
is switched Off or an AF Amp is switched Off while TKR-
750/850/751/851 is in Save Mode.
! Configuration of KPG-91D
" Configuring the Save Delay Timer A (Refer to
Note: The Power LED does not unlit even when sending a
10.4.2 Save Delay Timer B
You can configure a duration between the time when
TKR-750/850/751/851 enters into Save Mode and the
Save function is switched On (Display Off). You can also
configure a duration from the time when TKR-750/850/
751/851 switches from Busy status to Not Busy status to
the time when it enters Save On status.
! Configuration of KPG-91D
" Configuring the Save Delay Timer B (Refer to
10.4.3 Save Mode Duration
This function allows you to make TKR-750/850/751/851
automatically exit Save Mode when a configured time
elapses after it enters Save Mode.
Function Reference (FUNC)
10 POWER CONTROL
FPRG 6.4.3 "Others" tab (Optional Features).)
signal to an Auxiliary Input port or a PF key assigned to
the Display On function while TKR-750/850/751/851 is
in Save Mode.
FPRG 6.4.3 "Others" tab (Optional Features).)