20 FUNCTION PORT
Function Name
DC Power Save On/Off
Display Off
Display On
Display On/Off
Hold Time Disable
Hold Time Enable
Hold Time Disable/Enable
Local TX Disable
Local TX Enable
Local TX
Disable/Enable
Low Power Off*2
Low Power On*2
Low Power
On/Off*2
Monitor Off
47
TKR-750/850/751/851 switches the Save Mode On/Off when a signal is applied to the PF [DC
Power Save On/Off] input port.
You can use this function only when the signal is detected with the Down Edge.
Trigger Detection for Auxiliary Input Ports.)
All LEDs other than the Power SW LED located on the front panel unlit when a signal is applied to
the PF [Display Off] input port.
This function is enabled only when TKR-750/850/751/851 is in Save Mode.
When the signal is detected with the Down Edge, you cannot make all LEDs light when this
function is once switched On. It should be used with Display On function.
All LEDs on the front panel light when a signal is applied to the PF [Display On] input port.
This function activates only when TKR-750/850/751/851 is in Save Mode.
When the signal is detected with the Down Edge, you cannot make all LEDs unlit when this
function is once switched On. It should be used with Display Off function.
the LEDs located on the front panel is switched On/Off when a signal is applied to the PF [Display
On/Off] input port.
This function activates only when TKR-750/850/751/851 is in Save Mode. You can use this
function only when the signal is detected with the Down Edge.
for Auxiliary Input Ports.)
The Repeat Hold Time is disabled when a signal is applied to the PF [Hold Time Disable] input
port. You can configure this function only when at least one channel is configured as the Repeat
for Operation mode and the Repeat Hold Time is enabled.
When the signal is detected with the Down Edge, you cannot switch the Hold Time On when this
function is once enabled. It should be used with Hold Time Enable function.
The Repeat Hold Time is enable when a signal is applied to the PF [Hold Time Enable] input port.
You can configure this function only when at least one channel is configured as the Repeat for
Operation mode and the Repeat Hold Time is enabled.
When the signal is detected with the Down Edge, you cannot switch the Hold Time Off after this
function is once enabled. It should be used with Hold Time Disable function.
The Repeat Hold Time is switched disable/enable when a signal is applied to the PF [Hold Time
Disable/Enable] input port. You can configure this function only when at least one channel is
configured as the Repeat for Operation mode and the Repeat Hold Time is enabled. You can use
this function only when the signal is detected with the Down Edge.
Detection for Auxiliary Input Ports.)
The transmissions using the Local Mic PTT is disabled when the signal is applied to the PF [Local
TX Disable] input port. When the signal is detected with the Down Edge, you cannot enable the
transmission using the Local Mic PTT after this function is once enabled. It should be used with
Local TX Enable function.
The transmission using the Local Mic PTT is enabled when a signal is applied to the PF [Local TX
Enable] input port. When the signal is detected with the Down Edge, you cannot restrict the
transmissions using the Local Mic PTT after this function is once enabled. It should be used with
Local TX Disable function.
The transmissions using the Local Mic PTT is switched disable/enable when a signal is applied to
the PF [Local TX Disable/Enable] input port. You can use this function only when the signal is
detected with the Down Edge.
The transmission power is changed from Low to High when a signal is applied to the PF [Low
Power Off] input port. This function activates only when at least one channel is configured as High
for TX Power.
(Refer to 4.10 TX High Power.)
The transmission power is changed from High to Low when a signal is applied to the PF [Low
Power On] input port. This function activates only when at least one channel is configured as
High for TX Power.
(Refer to 4.10 TX High Power.)
The transmission power is switched High and Low when a signal is applied to the PF [Low Power
On/Off] input port. This function activates only when at least one channel is configured as High for
TX Power.
(Refer to 4.10 TX High Power.)
You can use this function only when the signal is detected with the Down Edge.
Trigger Detection for Auxiliary Input Ports.)
The Signalling Decode function is enabled when the signal is applied to the PF [Monitor Off] input
port. When a signal is detected with the Down Edge, you cannot switch the Monitor On after this
function is once enabled. This function does not operate when TKR-750/850/751/851 enables the
repeat operation. It should be used with Monitor On function.
Function Reference (FUNC)
Description
(Refer to 10.4 DC Power Save.)
(Refer to 6.5 Repeat Hold Time.)
(Refer to 6.5 Repeat Hold Time.)
(Refer to 20.2.1 Trigger Detection for Auxiliary Input Ports.)
(Refer to 20.2.1
(Refer to 20.2.1 Trigger Detection
(Refer to 20.2.1 Trigger