Building Disk Arrays - Hitachi Compute Blade 500 Series User Manual

Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

The building of disk arrays should be entirely performed with Configuration
Wizard.
Note: Do not change the disk array during system operations. If you
change the disk array, all data will be lost from those disks due to change in
the disk array.
Note: Set each item to the recommended value unless otherwise specific
directions are given. Otherwise, the system may not properly operate. We
have no responsibility for the malfunction due to the setting except our
recommended values. You can build 16 disk arrays maximum per Drive
Group.

Building disk arrays

This section describes the procedure for building new disk arrays.
Building disk arrays for RAID 0 and 1
Here is a procedure for building disk arrays for RAID 0 and 1.
Note: RAID0 with a single disk does not have redundancy. When an error
occurs in a disk, all data in the disk may be lost. We recommend that RAID1
should be created to improve fault tolerance with data redundancy.
1
Click Configuration Wizard in the main menu.
.
2
Click New Configuration or Add Configuration box, and then click
.
Next.
MegaRAID WebBIOS for LSI SAS 2008
Hitachi Compute Blade 500 Series EFI User's Guide
3-25