1. System Settings
"Encryption"-[Off]
Do not encrypt password.
Administrator's E-mail Address
1
Specify the Administrator's E-mail Address.
If a failure occurs in the machine or consumables need to be replaced, e-mail messages are sent to
the Administrator's E-mail Address by E-mail Notification function.
On e-mailed scanned documents, if the sender is not specified this appears as the sender's address.
When sending e-mail, administrator's e-mail address will appear as the sender's address under the
following conditions:
• The sender has not been specified and the machine's e-mail address has not been registered.
• The specified sender is not registered in the machine's address book and the machine's e-mail
address has not been registered.
When conducting SMTP authentication for the transmitted files, the Administrator's E-mail Address will
appear in the "From:" box. If you have specified the user name and e-mail address in [SMTP
Authentication], make sure to specify this setting.
Enter up to 128 characters.
On e-mailed scanned documents, if [Auto Specify Sender Name] is [Off], specify the sender.
E-mail Communication Port
Specify the port numbers for receiving E-mail. The specified POP3 port number is used for [POP before
SMTP].
The default setting for POP3 is "110".
The default setting for IMAP4 is "143".
Enter a port number between 1 and 65535 using the number keys, and then press the [ ] key.
E-mail Reception Interval
Specify, in minutes, the time interval for via POP3 or IMAP4 server.
The default setting is [On], "15" minute (s).
If [On] is selected, the time can be set from 2 to 1440 minutes in increments of one minute.
Max. Reception E-mail Size
Specify the maximum reception e-mail size.
The default setting is "2" MB.
Enter a size from 1 - 50 MB in increments of one megabyte.
E-mail Storage in Server
Specify whether or not to store received e-mails on the POP3 or IMAP4 server.
The default setting is [Off].