Mitsubishi Electric F700 Instruction Manual page 108

Hide thumbs Also See for F700:
Table of Contents

Advertisement

Types of Monitor
Increments
Option input terminal
states
Option output
terminal states
Load meter
0.1%
Cumulative
energization time
*2
Actual operation
time
*2, 3
Motor load factor
0.1%
0.01kWh/
Cumulative power
0.1kWh
Power saving effect
Variable
according to
Cumulative saving
parameters
power
PID set point
0.1%
PID measurement
0.1%
value
PID deviation value
0.1%
*1
Frequency setting to output terminal status on the PU main monitor are selected by "other monitor selection" of the parameter unit (FR-PU04).
*2
The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and accumulated again
from 0. When the operation panel (FR-DU07) is used, the time is displayed up to 65.53 (65530h) on the assumption that 1h = 0.001, and
thereafter, it is added up from 0.
*3
The actual operation time is not added up if the cumulative operation time before power supply-off is less than 1h.
*4
When using the parameter unit (FR-PU04), "kW" is displayed.
*5
The setting depends on capacities. (01160 or less/01800 or more)
REMARKS
⋅ By setting "0" in Pr. 52, the monitoring of output speed to alarm display can be selected in sequence by
⋅ When the operation panel (FR-DU07) is used, the displayed units are Hz, V and A only and the others are not displayed.
⋅ The monitor set in Pr. 52 is displayed in the third monitor position. (The output voltage monitor is changed.)
Initial value
* The monitor displayed at powering on is the first monitor. Display the monitor to be displayed on the first monitor and press
1s. (To return to the output frequency monitor, hold down
Power-on monitor (first monitor)
Output frequency monitor
Example)When Pr. 52 is set to "20" (cumulative energization time), the monitor is displayed on the operation panel as
described below.
Power-on monitor (first monitor)
Output frequency monitor
Pr.52 Parameter
Setting Value
PU Main
DU LED
Monitor
×
56
×
57
17
1h
20
1h
23
24
25
*4*5
50
51
52
53
54
• S
econd monitor
Output current monitor
• S
econd monitor
Output current monitor
Monitor display and monitor output signal
Description
Displays the input terminal ON/OFF states of the digital input
option (FR-A7AX) on the DU. (Refer to page 102 for details.)
Displays the output terminal ON/OFF states of the digital output
option (FR-A7AY) or relay output option (FR-A7AR) on the DU.
(Refer to page 102 for details)
Displays the torque current in % on the assumption that the Pr. 56
setting is 100%.
Adds up and displays the energization time after inverter shipment.
You can check the numbers of monitor value exceeded 65535h
with Pr. 563.
Adds up and displays the inverter operation time.
You can check the numbers of monitor value exceeded 65535h
with Pr. 563.
Can be cleared by Pr. 171. (Refer to page 103.)
Displays the output current value on the assumption that the
inverter rated current value is 100%.
Adds up and displays the power amount based on the output
power monitor.
Can be cleared by Pr. 170. (Refer to page 103.)
Displays the energy-saving effect monitor.
Can be converted into the charge display or % display by
parameter setting.
(Refer to page 120 for details.)
Displays the set value for PID control. (Refer to page 184.)
Displays the process value for PID control. (Refer to page 184.)
Displays the deviation for PID control. (Refer to page 184.)
for 1s after displaying the output frequency monitor.)
Third monitor
Output voltage monitor
Third monitor
Cumulative energization time monitor
.
Alarm monitor
With alarm
Alarm monitor
With alarm
for
3
101