Selection of operation mode and
operation location
(3) Controllability through communcation
Condition
Operation
(Pr. 551
Location
setting)
Item
Run command
(start, stop)
2
Running frequency
(PU
setting
connector)
Monitor
Parameter write
Parameter read
Inverter reset
Run command
(start, stop)
1
Running frequency
(RS-485
setting
terminal)
Monitor
Parameter write
Parameter read
Inverter reset
Run command
(start, stop)
Running frequency
1
setting
(RS-485
Monitor
terminal)
Parameter write
Parameter read
Inverter reset
Run command
(start, stop)
Running frequency
2
setting
(PU
Monitor
connector)
Parameter write
Parameter read
Inverter reset
Run command
(start, stop)
Running frequency
setting
Monitor
Parameter write
Parameter read
Inverter reset
Inverter reset
Run command
(start, stop)
Frequency setting
*1
As set in Pr. 338 Communication operation command source and Pr. 339 Communication speed command source. (Refer to page 151)
*2
At occurrence of RS-485 communication error, the inverter cannot be reset from the computer.
*3
At a PU stop, PS is displayed on the operation panel. As set in Pr. 75 Reset selection/disconnected PU detection/PU stop selection . (Refer to page
136)
*4
Some parameters may be write-disabled according to the Pr. 77 Parameter write selection setting and operating status. (Refer to page 139)
*5
Some parameters are write-enabled independently of the operation mode and command source presence/absence. When Pr. 77 = 2, write is
enabled. (Refer to page 38 for the parameter list)Parameter clear is disabled.
*6
When Pr. 550 NET mode operation command source selection = 1 (inverter RS-485 terminals valid) or Pr. 550 NET mode operation command source selection =
9999 and the communication option is not fitted.
*7
When Pr. 550 NET mode operation command source selection = 0 (communication option valid) or Pr. 550 NET mode operation command source
selection = 9999 and the communication option is fitted.
152
Operation
Mode
PU
External
Operation
Operation
×
PU stop
enabled
*3
×
×
*4
*5
×
×
PU stop
PU stop
enabled
enabled
*3
*3
×
×
×
×
*5
*5
×
×
×
*4
*5
×
×
×
×
×
×
*5
*5
×
×
×
×
×
×
×
×
*5
*5
×
×
×
×
External/PU
External/PU
Combined
Combined
Operation
Operation
Mode 1
Mode 2
(Pr. 79 =3)
(Pr. 79 =4)
×
PU stop
enabled
*3
×
*4
*4
×
×
PU stop
PU stop
enabled
enabled
*3
*3
×
×
×
×
*5
*5
×
×
*4
*4
×
×
×
×
×
×
*5
*5
×
×
×
×
×
×
×
×
*5
*5
×
×
×
×
NET Operation
NET Operation
(when RS-485
(when
communication
terminals are
option is used)
used)
*6
×
PU stop enabled
*3
×
×
*5
×
PU stop enabled
*3
×
×
*5
×
×
×
*5
×
*1
×
*1
×
*4
*5
×
*2
×
*1
×
*1
×
*5
*4
×
*2
×
*1
×
*1
: Enabled, ×: Disabled
*7